When using an electrical appliance, basic safety precautions should always be observed,
including the following
READ ALL INSTRUCTIONS BEFORE USING YOUR CORDLESS HAND VACUUM,
ALWAYS FOLLOW THESE SAFETY INSTRUCTIONS.
Replacement battery pack SKU# X8901
for Model EP750M
WARNING:
To reduce the risk of fire, electrical shock, or injury:
Call:1-866-98SHARK (1-866-987-4275)
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
1. Do not charge this unit outdoors.
2. Do not use outdoors or on wet surfaces.
3. Do not allow to be used as a toy. Close attention is necessary when used by or near
children.
or
4. Use only as described in this manual. Use only manufacturer’s recommended
attachments.
5. Do not use with damaged cord or plug. Do not use cordless hand vacuum if it has
been dropped, damaged, left outdoors, or dropped in water. Return it to EURO-PRO
Operating LLC for examination, repair or adjustment.
6. Do not abuse the charger cord. Never carry the charger or base by the cord or yank to
disconnect from an outlet; instead grasp the charger and pull to disconnect.
7. Keep charger cord away from heated surfaces.
FOR TECHNICAL SUPPORT
Dial: 1 800 798-7398
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time
8. This product includes rechargeable nickel cadmium batteries. Do not incinerate
batteries or expose to high temperatures, as they may explode.
9. Do not handle plug or appliance with wet hands.
10. Do not put any object into openings. Do not use with any opening blocked; keep free of
dust, lint, hair and anything that may reduce air flow.
11. Keep hair, loose clothing, fingers, and all parts of body away from openings and moving
parts.
12. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot
ashes.
Please Note
The Dust Cup Filter is washable. It should, however, be replaced every three
(3) months to ensure peak performance of your vacuum.
Important
Make sure that Dust Cup Filter is completely dry before re-installing back
in the hand vacuum.
13. Do not attempt to change accessories while unit is running.
14. Use extra care when cleaning on stairs.
15. Do not use to pick up flammable or combustible liquids such as gasoline or use in
areas where they may be present.
16. Look on your hand vacuum and follow all label and marking instructions.
17. Do not use charger with an extension cord. Plug charger directly into an electrical
outlet. Use charger only in a standard (120V., 60Hz) electrical outlet.
18. Keep end of hose, wands and other openings away from your face and body.
19. Do not use the hand vacuum cleaner without dust cup filter in place.
20. Store the cordless vacuum indoors. Put the cordless vacuum away after use to prevent
accidents.
21. Leaks from battery cells can occur under extreme conditions. If the liquid, which is 20-
35% solution of potassium hydroxide, gets on the skin - wash immediately with soap
and water or neutralize with a mild acid such as lemon juice or vinegar. If the liquid
gets into the eyes, flush them immediately with clean water for a minimum of 10
minutes and seek medical attention.
22. Use only on dry, indoor surfaces.
23. Do not use for any purpose other than described in this user's guide.
24. Do not attempt to use the charger with any other product nor attempt to charge this
product with another charger. Use only the charger supplied with this appliance.
25. The appliance must be disconnected from the supply when removing the battery.
26. The battery pack must be removed from the appliance before the unit is disposed of
safely.
27. The battery pack must be disposed of properly.
SAVE THESE INSTRUCTIONS
FOR HOUSEHOLD USE ONLY
8
Printed in China
Rev 06/03D
1
TM
TROUBLESHOOTING GUIDE
15.6 Volts
PROBLEM
POSSIBLE REASON
POSSIBLE SOLUTION
Model EP750M
1. Batteries discharged.
2. No power in electrical
outlet supplying
1. Charge unit.
2. Check fuse or breaker.
Replace fuse/reset
breaker.
HAND VACUUM WILL
NOT OPERATE
transformer.
3. Unit needs servicing.
3. Call 1 800 798-7398
1. Empty dust cup container
– (see page 4).
HAND VACUUM WILL
NOT PICK-UP OR
SUCTION POWER IS
WEAK
1. Dust cup container is full.
2. Dust cup filter needs
cleaning.
2. Remove dust cup filter
and check for object(s) in
air duct and remove.
Clean or replace dust cup
filter. (see page 4).
3. Unit needs recharging.
3. Charge unit.
1. Empty dust cup container.
2. Review dust cup filter
installation instructions.
(see page 4)
3. Replace dust cup filter.
(see page 4)
1. Dust cup container is full.
2. Dust cup filter is not
installed correctly.
3. Puncture/hole in dust cup
filter.
DUST ESCAPING
FROM HAND
VACUUM
8. Convertible Brush
9. Motorized Brush
10. Charging Adapter
11. Crevice Tool
12. Recharging Stand
13. Charging Jack
1. Dust Cup (Container)
2. Dust Cup Release Button
3. On / Off Switch
4. Dust Cup Filter
5. Charging Light Indicator
6. Main Unit
1. Remove tube and/or
bushes. Remove
obstruction from tube or
brushes.
2. Empty and clean dust cup
container.
HAND VACUUM
BRUSHES WILL
NOT PICK-UP
1. Extension tubes clogged.
2. Dust cup container is full.
7. Extension Tubes
NOTE: Cordless vacuum Model EP750M is shipped with the
batteries uncharged. Charging of the unit for 24 hours
prior to first use is required.
2
7
Battery Pack Replacement & Disposal
ASSEMBLY
This vacuum cleaner contains a nickel-cadmium (Ni-Cd) batteries. Batteries must
be recycled or disposed of properly. Call your nearest recycling center for
information on the recycling and disposal of nickel-cadmium (Ni-Cd) batteries.
If uncertain as to how to remove the battery pack, we suggest you take your hand
vacuum to a reputable small appliance service technician to have this service
preformed.
Note: Dust cup filter (4) must be used when operating the hand vacuum.
1. To open the dust cup (container) (1), push button (2) and remove the dust cup (1).
Verify that the dust cup filter (4) is inside, then re-attach the dust cup (container) (1)
to the hand vacuum.
The battery pack of your EP750M is replaceable, however care should be taken
when doing so. Follow these steps when replacement is required:
1. Remove unit from charging stand and /or remove the charging adapter jack,
before changing batteries. Ensure that the “on / off” switch is in the “off”
position.
2. Open the battery pack compartment by removing the single Phillips head
screw located in the recess at the rear of the unit. NEVER open the battery
compartment except to change the battery pack when required.
3. Remove battery compartment cover. Set aside battery compartment cover
with the screw.
Fig. 1
Fig. 2
Fig. 3
2. To attach the convertible brush (8), or crevice tool (11) to the Hand Vacuum, push the
attachment into the suction hole, as shown in Fig.4.
4. Carefully detach the two (2) electrical connectors from the battery pack by
pulling straight out from the battery pack.
5. Lift out the battery pack and set aside.
IMPORTANT: Use only Charging
Adaptor No. AD-2425-UL supplied
with this unit.
6. Insert the new battery pack and re-connect the terminals by pushing lead
wires onto battery tabs.
7. Tuck the wiring inside the battery compartment so that the wiring does
not interfere with the battery compartment cover when it is
replaced.
8. Re-install the battery compartment cover by sliding it over the battery
towards the front of the unit, making sure that the front snap engages the
body of the unit.
Fig. 4
3. To operate the motorized brush, connect the plug of the spiral cord of the brush to
the jack under the bottom of the main unit, then turn on the unit
for vacuuming. (Fig5, 6)
9. Replace the battery compartment cover screw.
WARNING: NEVER use ordinary
batteries for replacement, as these may
leak and damage your vacuum cleaner.
Use only battery pack X8901 provided
by EURO-PRO Operating LLC for
replacement.
Fig. 5
Fig. 6
4. To use the extension tubes (7) with the motorized brush (9), push the extension tube
with the rubber seal into the suction hole of the dust cup , then insert the other
extension tubes into each other and then insert the motorized brush (9) into the last
extension tube. Operate the motorized brush as shown in Point 3 above. The
convertible brush (8) and the crevice tool (11) can also be used with the extension
tubes (7).
CAUTION
• Use only with the battery pack
supplied with the unit.
• Do not attempt to remove the battery
CAUTION: NEVER use the unit
without the battery compartment cover
pack from the unit to charge it.
in place.
• Never attempt to throw the battery
pack or unit into a fire or incinerate it.
• Do not attempt to remove or damage
the battery casing.
Insert extension tube with seal
into dust cup suction hole
NOTE: Any other servicing should be
• Battery must be recycled or disposed
performed by an authorized service
representative.
of properly at the end of it's
service life.
3
6
HOW TO OPERATE YOUR CORDLESS VACUUM
CHARGING THE CORDLESS VACUUM
1. Connect the charger jack to the charging hole on the underside of the
charging stand. (See fig. 1) Plug the the charging transformer into the wall
outlet.
2. This vacuum cleaner is powered by Ni-Cd batteries. Before first use,
they must be charged for a minimum of 24 hours.
3. Once the batteries are fully charged, the vacuum cleaner will run for up to
20 minutes before recharging is required.
4. To recharge, simply dock the vacuum cleaner in the charging stand, with the
switch in the “off” position. Make sure that the unit is well seated and that the
charging light is illuminated. Charging times will vary depending upon the
amount of usage between charging cycles.
Your cordless vacuum operates when the batteries are fully charged.
Before using, please ensure that the cordless vacuum is initially charged for
24 hours.
IMPORTANT: Use only Charging Adaptor No. AD-2425-UL
supplied with this unit.
CAUTION: The Cordless Vacuum is a very powerful unit. Make
sure that you hold it firmly, otherwise it can slip out of
your hand and cause injury.
5. The charging light indicator (5) on the vacuum cleaner will illuminate to indicate
that the vacuum is properly charging.
NOTE: Peak performance may only be realized after the
unit has been charged and discharged two (2) or
three (3) times.
CHANGING & CLEANING THE DUST CUP FILTER
To achieve the best performance, empty the dust cup (# 1 ) and clean
the dust cup filter (# 4 ) after each use.
1. To open the Dust Cup container, press down on the release button
and pull out the Dust Cup container (fig. 1).
IMPORTANT: To maintain peak performance of your
cordless hand vacuum, it is recommended
that the unit be fully discharged, then
2. Pull out the Dust Cup Filter (fig. 2).
3. Empty the dust from the Dust Cup Filter, (fig. 3).
4. Rinse the Dust Cup Filter in warm water, and then wait until it dries
completely before replacing it into the Dust Cup container.
completely re-charged at least once a month.
5. Place the Dust Cup Filter carefully into the Dust Cup container.
6. Attach the Dust Cup container to the Cordless Vacuum.
Fig. 1
Fig. 2
Fig. 3
NOTE: It is recommended that the dust cup filter be changed every
three (3) months to ensure peak performance of the unit.
CAUTION: The suction hole must be free of obstructions at all times.
Otherwise, the motor will overheat and could become
damaged.
Charging
Receptacle
Fig. 1
4
5
|